TECHNICAL DATA
Power supply | 10..40 Vdc, 19..28 Vac (@50..60 Hz) |
Power consumption | 2,5 W |
Insulation | 1.500 Vac a 5 vie |
Accuracy class | 0,01% |
Status LED | Power supply Error Tx Data Rx Data Digital I/O Load cell overload |
Input channels | 1 analog channel for reading (and power supply) up to 4 (350 Ω) or 8 (1,000 Ω) strain gauge load cells, 4 or 6-wire connection, equivalent impedance 87 Ω 1DI tare calibration or weight threshold |
Output channels | 1 analog retransmission channel of the net weight in current (0...20, 4...20 mA) or in voltage (0..5, 0..10 V); 1DO tare calibration or weight threshold |
Advanced features | Tare acquisition Stable weighing signaling via Modbus Tara Silos function Counting function Tare reset function Data logging on EASY Setup |
Advanced settings | Analog output with programmable limits Upgradeable firmware I/O independent digital Wide-range settable sampling rate Alarm threshold with programmable hysteresis Fully configurable analog output Configurable resolution |
Measurements | ADC 24 bit Ratiometric measurement Floating-point integer value The minimum net weight value Stabilized measurement with noise filter |
Measurement / Diagnostics | Sensitivity from 1 to 64 mV/V |
Thermal drift | 25 ppm/K |
Interfaces | 1x RS485 serial port 2 wires speed up to 115.200 bps 1x 100Mbit Ethernet port |
Supported protocols | ModBUS RTU ModBUS TCP-IP |
Data | EEPROM for configuration parameters, retention time 40 years |
Connections | Removable screw terminals for conductors up to 2.5 mm² MicroUSB port on the front panel |
Programming | Web server |
Protection degree | IP20 |
Mounting | For DIN rail guide 35 mm DIN 46277 |
Operating temperature | -25..+70°C |
Dimension (WxHxD) | 17,5x100x112 mm |
Weight | about 140 g |
Housing | Nylon 6 preloaded 30% glass fiber, self-extinguishing class V0 |
Standards | CE |
Norms | EN 61000-6-4/2002, EN 61000-6-2/2002, EN 61010, EN 60742, IEC 61131 |
SHIPPING AND EXPORT INFORMATION
PRODUCT CODE | ZE-SG3 |
GROSS WEIGHT kg | 0.18 |
ORIGIN | IT |
CN (Combined Nomenclature) | 85389091 |
ECCN | 5A991 |
Manuales, flyer
Tools
![zip icon](/assets/images/icons/ZIP.png)
Firmwares
DISEÑOS Y MODELOS CAD
Certificados
Accesorios
Productos alternativos
SENECA offices will be closed from August 3 to August 25 included. Business activities will resume regularly on Monday 26 August. Orders received from July 30 will be shipped from August 26. We wish you happy summer holiday!
Versiones del producto
Aaccesorios
Equalization and connection circuit up to 4 load cell in parallel + IP66 box including mm diamter cable glands 7 and 2 hole covers
Disponibilidad para confirmar, contáctenos ?