TECHNICAL DATA
Power Supply | 10..40 Vdc; 19..28 Vac |
Auxiliary voltage output | 12 Vdc / 40 mA |
Max Consumption | 3 W |
Max Isolation | 1.5 kVac |
Status Indicators | Power supply Input / Output status STS (IP address / DHCP) RX / TX (Receive / transmit data over RS485) Ethernet TRF / LNK (Transit packets / Ethernet connection) |
Protection Degree | IP20 |
Operating temperature | -25..+65°C |
Dimensions (WxHxD) | 106 x 90 x 32 mm |
Weight | 170 g |
Housing | Pc/ABS material self-extinguishing UL94-V0, black colour |
Connections | 3.5mm pitch terminals, Micro USB connector and double RJ45 connector |
Mounting | On DIN EN 60715 rail, wall-mounted / panel-mounted |
Programming | SENECA Studio Configurator, Integrated web server, DIP-switch |
Special Features | Double Ethernet Daisy Chain connection LAN fault bypass (the active connection between the two Ethernet ports of the device in case of power failure) Max 32 Peer to Peer Rules (I/O Mirror) - No need for Master Modbus Passthrough (TCP-IP to RS485) IP, MAC, Firmware identification and configuration by SDD tool |
Data Memory | FeRAM for counters backup |
Interfaces | Nr.2 Ethernet ports (with LAN fault-bypass function) 100 baseT on RJ45 - 100 Mbps (TCP-IP) Nr.1 RS485 port on terminals M23-M24-M25 - 115.200 bps (RS485) Nr.1 Micro USB (programming) |
Protocols | ModBUS RTU, ModBUS TCP-IP, HTTP |
Cable for Ethernet communication between devices | CAT5 or CAT5e unshielded |
ModBUS Communication | Up to 64 nodes without repeater and max speed 115 kbps |
ANALOG INPUT CHANNELS | |
Number of Channels | 8 Analog |
Type and Range | Voltage: -30 V ÷ -30 V; -120m V ÷ +120 mV Current: -24 mA ÷ +24 mA Thermocouple: J, K, T, E, N, R, S, B, L Thermoresistor Pt100 on AI1: -200 °C ÷ +200 °C (only for cold junction comp.) |
DIGITAL INPUT/OUTPUT CHANNELS | |
Number of Channels | 8 Digital Inputs/Outputs |
Type and Range | Inputs = voltage: ON threshold: > 9 V; OFF threshold: < 4 V; Vmax: 24 V; Impedance: 9 kΩ Outputs = MOSFET, PNP; max. voltage/current: 0.2 A / 24 V |
STANDARD | |
Certifications | CE |
Homologations and Standards | EN61000-6-4, EN61000-6-2, EN61010-1 |
Manuales, flyer
Firmwares
DISEÑOS Y MODELOS CAD
Certificados
Productos relacionados
Productos alternativos
SENECA offices will be closed for Christmas holidays from 24 December to 6 January. Business activities will resume as normal on Monday, 7 January. Orders received from 20 December will be dispatched from Monday, 7 January. We thank you for your cooperation and wish you happy holidays!