Energy Power Meters - Energy Management Systems

r203-x-l-h.png
03
3.1

These energy power meters are designed specifically to detect power supply details in single-phase or three-phase loads networks. S203s allow energy and power analysis and the power quality control. They support the communication protocol ModBUS RTU

TAA and TAC Series - Current Transformers

taa.png
03
3.2

TA Series current transformers are 0.5 accuracy class components available in open-core (for easy installation applications), primary wound (for low primary current values), and busbar (for high primary current values) versions. They can be used for current measurement on both cable and busbar systems. They are the ideal supply complement for current measurements in combination with network analyzers, energy meters, and electrical measurement converters. TA Series current transformers are installed to reduce the line current to a value of up to 5 A on the output secondary circuit.

Rogowski Coils

rc150.png
03
3.3

Rogowski trasducers RC150/RC190 are flexible coils without magnetic core, in toroid form, placed around the current carrying conductor. The variable magnetic field produced by the current induces a voltage in the coil. The length of the coil ranges from 25 up to 180 cm while the diameter of the rope is reduced up to about 8 mm.

Energy Counters - S500 Series

s504c.png
03
3.4

S500 Series energy counters are used for industrial and civil environment energy measurement. These are available with embedded communication interfaces such as ModBUS TCP-IP, ModBUS RTU, M-BUS or through external interface modules. These counter are avaible with MID certification. LCD display shows totalizers and instantaneous powers.

Current Transducers - T201 Line

t201dch100-300-mu.png
03
3.5

T201 Series AC/DC current trasducers are able to convert the value of the measured current (up to 300A) in an industrial signal 4..20mA or 0..10V. They are available in different sizes and models, including models with patented measuring principle that avoids the thermal drifts.

Energy Measurements Converters

z2041.jpg
03
3.6

These energy measurements converters can measure voltage and current (both AC and DC) values converting them into a standardized current signal or voltage to the output terminals, proportional to the input value. The scaling parameters of the inputs and outputs are selectable via software or DIP switch.

RTU / Controllers for Energy Management

z-pass2-rt.png
03
3.7

For Energy Management applications SENECA introduces different CPU like Z-TWS4-E based on IEC 60870-5-101 protocols, IEC 60870-5-104, IEC 61850 and plant automation (Straton - Soft PLC IEC 61131-3). In the same application field MyALARM2-CEI 0-16 is a GSM unit that allows the network operator remote interruption via encrypted SMS.

Accessories

tools.png
03