TECHNICAL DATA

Power supply 7..30 Vdc (da loop 4..20 mA)
Hot swapping Yes
Max power consumption 24 mA
Max power dissipation < 660 mW
Insulation 1,5 kVac (2 vie)
Status LED Anomaly
Alarm
Accuracy Class 0,1%
Input type Cu50, Cu100
Pt100, Pt500, Pt1000
Ni100, Ni120, Ni1000
TC J, K, R, S, T, B, E, N, L; input impedance 10 MΩ
Potentiometer: 500 Ω..100 kΩ
Voltage: -150..+150 mV; input impedance 10 MΩ
Voltage: -30..+30 V; input impedance 200 kΩ
Current: -24..+24mA; impedance 40Ω
Resistance 0..+400 (1.760) Ω
Output channel Current 4-20 mA (passive)
Filter Additional for reading stabilization
Special functions Cold junction compensation
Insertable filter
Output reversal
A/D conversion 16 bit
Thermal drift <120 ppm/K
Connection 8 spring clamps
Rejection 50 o 60 Hz (programmable)
Programming EASY SETUP
Insulation technique Digital / Optocoupler
Processing 32 bit floating point calculation
Protection degree IP20
Housing PBT, nero
Dimension (WxHxD) 6,2x93,1x102,5 mm
Weight 45 g
Operating temperature -20..+65°C
Standard CE
Norms EN 61000-6-4, EN 61010-6-2, EN 61010-1

SHIPPING AND EXPORT INFORMATION

PRODUCT CODE K121
GROSS WEIGHT kg 0.075
ORIGIN IT
CN (Combined Nomenclature) 85437090
ECCN EAR99

 
IT EN FR DE ES
Datasheet
pdf icon it pdf icon en - - -
K-Series converters range flyer
pdf icon it pdf icon en - - -
Installation Manual
pdf icon it pdf icon en pdf icon fr pdf icon de pdf icon es

ЧЕРТЕЖИ И CAD МОДЕЛИ

 
2D model
dwg icon Multi
3D Model
dwg icon Multi
3D Model (electrical symbols)
dwg icon Multi
3D Model
stp icon Multi

 
CE Conformity Declaration
pdf icon Multi
REACH and ROHS declarations
pdf icon Multi
Customs codes
pdf icon Multi
0
0
2

Product versions

Price
K121

Loop powered universal converter

?
90,00
K121-C

[K121-C] Loop powered isolator / universal converter - presetted version (please specify configuration settings in order notes)

?
104,00


Price
EASY-USB

USB - UART TTL converter

?
74,00
S117P1

RS232/USB, TTL/USB, RS485/USB serial converter

?
180,00