========================== Z-TWS4/Z-PASS2-S/S6001-RTU Z-PASS2-S-R01 Z-PASS2-S-IO SW Rel. SW002940_332 Release Note ========================= ------------------ nuove funzionalitą ------------------ - Added new Mobile Network Firewall. - Added algorithm to avoid blocking the SIM in case of incorrect PIN. - Added manual provider selection (only for devices with Quectel modem). - Added DDNS (Dynamic DNS) service. - On readVariable and writeVariable CGI, variables of type LREAL are now managed. - Added integration with Z-NET4 for management digital I/O (for devices with I/O on-board). - In the "Main View" page of the Web Server, the "RESET" button has been renamed to "RESTART". - Hidden the "Mobile Configuration" section on the Z-TWS4 Web Server. Hidden the "Modem Available" parameter on the "Mobile Network" page. - Added a modem reset (only for devices that support it) when CPU restart. - Added a new level (4 = "SMS Service") of "Security Level / Service Disable". - Added a new function block SERVICE_CTRL. ------------------- correzione anomalie ------------------- - Fixed problem on the "Modbus Modules" page: now "Digital I/O Configuration", "I/O View" (S6001-RTU) works with Microsoft Edge and Internet Explorer browsers. - Fixed problem on the "Network and Services" page: reboot was always performed when at least one of the Web server's port parameters was not enabled. - Added control on "Upgrade and Reboot" and "Cancel and Reboot" buttons (on "FW Upgrade" page) to prevent twice action on repeated double-clicking. - Fixed problem that caused abnormal operation to the find modules function. - Fixed the readVariable and writeVariable CGI in order to return the result "Operation timeout", instead of "Slave not found", for a slave ID not allocated to any serial port,   so the "Find Modules" function from Z-NET4 proceeds even in the presence of "holes" in the requested range address. - Fixed the PPP process termination in "brute mode". - Fixed an issue that caused the replacement of the '_' character with the '§' character in the SMS sending FB. - Fixed DOs management of DOs not configured as "General Output" in Straton. - Fixed an issue that caused the replacement of the '+' character with the ' ' character in a string sent to the CPU through Web Factory. - Fixed of a problem that caused the non-synchronization of the Straton variables using the readVariable CGI. - Fixed of reboot problem caused by the block of the watchdog process in the execution of the system watchdog function. - Introduced periodic delete of temporary files of failed function blocks for TIMEOUT. - Introduced the "close on exec" management on listen sockets of PLC processes. ---------------------- funzionalitą eliminate ---------------------- - Remove support for "Z-TWS4-L", "Z-PASS2-L" - Remove support for "Z-MODEM-3G" ---------------------- versioni componenti FW ---------------------- kernel=2.6.28 #137 PREEMPT Tue Jun 20 10:46:10 CEST 2017 initrd=Jun 1 13:55:29 2017 rootfs=226_20171103 diskdfl=SW002940_332 disk=SW002940_332